How to Install an Electric Tap Box

According to NEC, re should be no splices of wires outside of an enclosure that is approved. One type of such box is junction box. This box is a standard one securely fixed on a suitable structure and contains splice (wiring collection) of two or more wires or circuit cables. Cable clamps are used to secure cables to box. To come up with complete enclosure, there needs to be a removable cover on the junction box. The cover should be easily accessible and should not be drywall or surface material.

Supplies Required:

  1. Switch off power and test wires
    Ensure that power to the circuit you will be working on is turned off. This can be achieved by turning off circuit breaker in service panel of your home. Use a non-contact voltage tester to test all wires you will be operating on. This test will enable you to confirm that any of wires have no voltage present in m.
  2. Take out the knock out of a metal box.
    Remove knock out on the box for every cable that is supposed to enter the box. In case you are using a metal box. You can remove each knock out using a hammer and screwdriver n twists it off with pliers.
  3. Clamp Each Cable
    Just as required, install cable clamp for every cable. Reis no knockouts in standard plastic Electric boxes. However, y have internal cable clamps. Internal clamps may be present in Metal boxes. If re is none in your box, consider installing locknut-type clamp for every cable. Place end of camp that is threaded through A Knock out hole and fix clamp inside the box using the nut. Use pliers to tighten the nut.
  4. Mount Box
    Make room for new junction box by separating circuit wires at existing splice and loosening cables as required. Using screws driven through factory made holes in back or side of box, mount box to framing as applicable.
  5. Secure cables
    Feed cables into the box via a clamp. Ensure that cable sheathing extends half to One-inch past clamp and cable wires extend approximately six inches into the box. Trim wires If re is need and strip A three-quarter inch of insulation from every wire utilizing wire strippers. Tighten screws on clamps to secure cables. Be careful to ensure that you do not over-tighten cables to avoid damaging m. You do not need to tighten plastic boxes because y have spring-tabs for clamps. Ensure that end of each wire is clean, straight and is not damaged. Strip it insulation should be stripped A half to three quarters from ends. Any wires and strips insulation that is damaged need to be trimmed using a wire stripper to level are needed.
  6. Join wires
    Following instructions of the manufacturer, utilize wire connectors to join wires together. First, join together bare copper ground wires. Consider adding a pigtail to ground wire connection, for a metal box. The pigtail is the six-inch length of a similar type of ground wire. The loose end of pigtail should n be connected to the ground screw on the box. Join together each of following wires. White (neutral) ones together. Black (hot) ones together. Finally, join together in case re are red (hot) wires.

Tug on each wire gently to confirm that is all secure.

Tuck wires into box carefully n install box cover and secure it with two screws. Ensure that cover you take is black solid without holes. Switch on the circuit breaker to restore power to the circuit.

Source: Fox FabElectrical Tap Box

Why You Should Install A Generator Docking station

August 2015 is a day that will forever remain significant to residents of BC’s south coast. The township was hit by a massive storm which left downtown roads impassable due to trees which had toppled all over and a blackout that lasted for hours on end. According to a report by BC hydro, approximately 500, 000 people were left in the dark that day while many others still had no electricity two days later.

Unfortunately, the power outage often means losses to many businesses because not much can be achieved. That is why it is essential for a company to be prepared for anything that might come up and one way to do that is through generator docking. Once it’s set up, a docking station offers a single point to connect a portable generator and once there is a power outage, all a business person needs to do is connect the generator to the tap box, switch from the standard power supply system to the temporary portable generator.

We recently had an interview with an experienced electrical engineer who emphasized on why it is essential to have a generator docking station set up in your business premise or even at home and below are some of the crucial tips we collected for you.

Safety Purposes

One of the first ethics of a business is that it should ensure all the employees and visitors are safe at all times. Without a generator docking station that is not possible because it means the power cable has to run from a generator to the main electrical room which is often not in a suitable spot.

For instance, some premises have their electrical department room situated up the stairs, basement or new the main doorways. That means your employees will no longer be safe as they are exposed to the risk of tripping on the cables or even being electrocuted. By having a docking station, you will not only reduce these risks but also make it easier to get things running again.

Everything Runs As It Should

Lacking power backup could cost your business a lot of money. For instance, in a report released by the electrical power research institute, power outages cost the country as a whole approximately $104 and $164 billion in a year because they are not able to get the bounce back to business as soon as possible. That is why having a generator could prove to be lifesaving. Reason being, the company can quickly connect their generator to the docking station and continue with its activities of the day.

It’s Not A Matter Of Ifs

Before last August no resident of lower mainland BC would have believed that there would be a mass blackout incidence until it did. A body is known as Allianz global corporate and specialty(AGCS) recently announced that people should expect more blackouts due to aging infrastructure and a few other factors and in BC, the risk often differs depending on the location. For instance, most of the mountainous areas of BC often undergo such incidences due to storms which topple trees on the power lines.

Findings from a survey conducted by BC Hydro show that regions such as Haida Gwaii might experience an outage which lasts up to thirty-six hours annually. That is why when you consider all these facts it is only advisable that you back up your business using a generator docking station and avoid risking the loss of profits and customers. It’s not a matter of ifs but a matter of business as usual.

Generator Docking Stations Are Economical

Even though larger institutions such as schools, hospitals, and other more significant setups use permanent backup solutions such as generators, they are quite costly and not an ideal solution for small business owners. For instance, according to a particular engineer magazine, installing a permanent 100Kw generator costs approximately USD 57,000 while setting up the same generator as a temporary solution costs about USD 16,000 and that is inclusive of the costs of installation and the purchase.

Thus when you consider all the benefits which come with installing a generator docking station and the low price of installation it is only reasonable if you take that path and secure your business from any uncertainties in future.

Written by Fox FabPortable Generator Tap Box

Dual-Purpose Generator Docking Station

Whether your project is a new one or just a remodel, our dual-purpose docking station will fit into it comfortably. The unit is stationed next to a permanent and the respective ATS. A portable generator and a load bank can be connected simultaneously. It again saves time and labor when you need to do service work to the permanent generator and eliminates the amount of cable that you need to hard wire into the main breaker. We have an industry kirk key mechanism which we can use on a standard dual-purpose docking station to transfer power from permanent generator to the portable.We install these with a quick and easy system of two bolts.

FEATURES:

AVAILABLE OPTIONS

Variety of beakers, utility light, NEMA 3R, two wire auto start, pad lockable swinging front door, block heater receptacle, a little device for monitoring, battery charger duplex receptacle and more.

Posted by FoxfabGenerator Connection Box